消防专家

机柜保护-完整和紧凑

开关和控制柜, 和自动售货机一样, 将电子和电子元件置于非常狭窄的空间内. CPS 1230 extinguishing systems protect this type of cabinet in case a fire occurs inside them as a result of a short circuit, 过载, 过热或组件错误.

优势一览

The CPS 1230 cabinet protection system (CPS) is a standardized comprehensive set with all necessary components in one package. The system is specially designed 为 fire protection of the sensitive and high-quality electronics in control cabinets and offers reliable and residue-free extinguishing through the use of the non-conductive Novec™ 1230 extinguishant by 3M™. 整套设备可方便地在现场安装, 在新安装和改造的情况下都是如此.

  • CPS 1230灭火系统用电子和电气部件保护机柜
  • The system prevents the fire from spreading to other facilities in the vicinity of the protected cabinets
  • 能源供应和生产设施无长时间停工
  • 一个系统可以保护两个机柜
  • The Novec 1230 extinguishing agent is neither corrosive nor electrically conductive and does not leave any residues
  • 新系统可以方便快捷地安装或改造

设计

CPS 1230灭火系统由灭火喷嘴和相关的供应管线组成, 灭火罐以及火灾探测和灭火控制系统. 一个系统最多可保护两个机柜的电子和电气元件.

1
灭火剂供应
2
火灾探测和灭火控制面板
3
感烟探测器
4
灭火剂喷嘴
5
电喇叭
6
灭火剂线
开关柜灭火系统的设计
  1. 灭火剂供应
  2. 火灾探测和灭火控制面板
  3. 感烟探测器
  4. 灭火剂喷嘴
  5. 电喇叭
  6. 灭火剂线

开关柜灭火系统是如何工作的?

CPS 1230灭火系统用于保护机柜内的火灾, 3MTM使用NovecTM 1230灭火剂. 灭火剂从火中提取热量,从而停止燃烧反应. Novec 1230灭火剂以液态储存在灭火剂罐中. The extinguishing agent is trans为med into a gaseous state only when it is released from the extinguishing nozzles into the cabinets that are to be protected. Novec 1230既不腐蚀也不导电, 无残留,非常环保.

一个CPS 1230灭火系统可以保护多达两个机柜的电子和电气组件. 多亏了预制组件集, 安装新系统或改造现有系统既简单又快捷. CPS 1230灭火系统在火灾的情况下不仅保护实际的机柜, 但也要防止火势蔓延到附近的其他设备.

火灾探测与控制技术

火灾报警与灭火控制技术

尝试并测试了Minimax 火灾探测与灭火控制技术 确保可靠的火灾探测以及系统的控制和功能监控. 每个受保护的机柜都有烟雾探测器进行监控. 与热探测器, these already transmit a signal to the fire detection and extinguishing control panel in the initial stages of a fire.

The control panel then initiates the shutdown of the energy supply of the cabinet and controls the electric triggering device of the extinguishing agent tank to ensure that the extinguishing agent can flow into the cabinet. 同时, 它触发一个警报,并可选地发送一个信号到一个永久的有人值守的岗位.

灭火剂储罐

Two differently sized CPS 1230 extinguishing agent tanks provide protection 为 all common cabinet sizes. 灭火剂容器可以直接放置在保护柜内,也可以放置在外部, 在橱柜上或橱柜旁边. 在灭火剂罐里, a cushion of nitrogen covers the extinguishing agent and thus generates an operational pressure of 42 bar. 灭火剂罐内装有一个带集成电触发装置的阀门.

配备供应管线的灭火喷嘴

保护柜上部安装CPS 1230灭火喷嘴. The special geometry of the CPS 1230 nozzles with a spraying angle of 210° ensures that the extinguishing agent is homogeneously distributed throughout the entire cabinet in the event of fire. 灭火喷嘴和灭火剂罐应连接相应的供水管路.

应用程序

CPS 1230机柜保护系统在许多情况下都是理想的消防解决方案.g. 为 低压开关系统中的开关柜, 控制柜用于生产系统或 出售商品和服务的自动售货机 与通勤运输系统有关. CPS 1230灭火系统用于机柜保护不仅保护财产, 但也防止能源供应和生产设施的停机时间延长.

开关柜
开关柜

防护区

风险

消防

mg冰球突破试玩送2000